Isolated Digital Outputs
48 VDC Out, Positive Logic
HE800DQM303 / HE-DQM303*
(16 Outputs)
*HE- indicates plastic case
1 SPECIFICATIONS
OUTPUT DIQ303
General Specifications
See Compliance Table at http://www.heapg.com/Support/compliance.htm Information is subject to change without notice. SmartStack is a trademark of Horner APG, LLC. 10 NOV 2006
MAN0544-03
2.1 Bottom
Connector
OCS Bottom View – Shows
Corresponding I/O Pin
Load Power
Power input range: 6–54 VDC. C1 is isolated from bus common. MAN0544-03
10 NOV 2006
3 INTERNAL
Note 1: Specification for transient voltage suppressors (transorbs) used on output
circuitry is 54 V, 600 W.
Note 2: Specification for transient voltage suppressors (transorbs) used on output
circuitry is 54 V, 400 W.
4 CONFIGURATION
Note: The status of the I/O can be monitored in Cscape Software.
Preliminary configuration procedures that are applicable to all SmartStack™ Modules are located in the Control Station Hardware Manual (MAN0227). Selecting the I/O Map tab provides information about the I/O registers, which are assigned to a specific
SmartStack™ Module and where the module is located in the point map. The I/O Map is determined by
the model number and location within the SmartStack™. The I/O Map is not edited by the user.
The Module Setup is used in applications where it is necessary to change the default states of the
outputs when the controller (e.g., OCS100) enters idle/stop mode. The default turns the outputs OFF
when the controller enters idle/stop mode. By selecting the Module Setup tab, each output can be set to
either turn ON, turn OFF or to hold the last state. Generally, most applications use the default settings.
Warning: The default turns the outputs OFF when the controller enters idle/stop mode. To
avoid injury of personnel or damages to equipment, exercise extreme caution when changing
the default setting using the Module Setup tab.
Information is subject to change without notice. SmartStack is a trademark of Horner APG, LLC. 10 NOV 2006
MAN0544-03
5 DERATING
INSTALLATION / SAFETY
Warning: Remove power from the OCS controller, CAN port, and any peripheral equipment
connected to this local system before adding or replacing this or any module.
Use the following wire type or equivalent: For detailed installation and a handy checklist that covers panel box layout requirements and minimum clearances, refer to the hardware manual of the controller you are using. (See the Additional References section in this document.). When found on the product, the following symbols specify: Warning: Consult user documentation.
Warning: Electrical Shock Hazard.
WARNING: To avoid the risk of electric shock or burns, always connect the safety (or earth)
ground before making any other connections.
WARNING: To reduce the risk of fire, electrical shock, or physical injury it is strongly
recommended to fuse the voltage measurement inputs. Be sure to locate fuses as close to the
source as possible.
WARNING: Replace fuse with the same type and rating to provide protection against risk of fire
and shock hazards.
MAN0544-03
10 NOV 2006
WARNING: In the event of repeated failure, do not replace the fuse again as a repeated failure
indicates a defective condition that will not clear by replacing the fuse.
WARNING: Only qualified electrical personnel familiar with the construction and operation of
this equipment and the hazards involved should install, adjust, operate, or service this
equipment. Read and understand this manual and other applicable manuals in their entirety
before proceeding. Failure to observe this precaution could result in severe bodily injury or loss
of life.
For detailed installation and a handy checklist that covers panel box layout requirements and minimum clearances, refer to the hardware manual of the controller you are using. (See the Additional References section in this document.): • All applicable codes and standards need to be followed in the installation of this product. • For I/O wiring (discrete), use the following wire type or equivalent: Belden 9918, 18 AWG or Adhere to the following safety precautions whenever any type of connection is made to the module. • Connect the green safety (earth) ground first before making any other connections. • When connecting to electric circuits or pulse-initiating equipment, open their related breakers. Do not make connections to live power lines. • Make connections to the module first; then connect to the circuit to be monitored. • Route power wires in a safe manner in accordance with good practice and local codes. • Wear proper personal protective equipment including safety glasses and insulated gloves when making connections to power circuits. • Ensure hands, shoes, and floor are dry before making any connection to a power line. • Make sure the unit is turned OFF before making connection to terminals. Make sure all circuits are de-energized before making connections. • Before each use, inspect all cables for breaks or cracks in the insulation. Replace Information is subject to change without notice. SmartStack is a trademark of Horner APG, LLC. 10 NOV 2006
MAN0544-03
7 ADDITIONAL
REFERENCES
The following information serves as a general listing of Horner controller products and other references of interest and their corresponding manual numbers. Visit our website listed in the Technical Support section to obtain user documentation and updates. Note: This list is not intended for users to determine which products are appropriate for their
application; controller products differ in the features that they support. If assistance is required,
see the Technical Support section in this document.
Controller Manual
LX Series (e.g., LX-xxx; also covers RCS116) OCS (Operator Control Station) (e.g., OCS1xx / 2xx; Graphic OCS250) Remote Control Station (e.g., RCS2x0) MiniOCS (e.g., HE500OCSxxx, HE500RCSxxx) Other Useful References
Wiring Accessories and Spare Parts Manual Wiring Accessories and Spare Parts Manual 8 TECHNICAL
For assistance and manual up-dates, contact Technical Support at the following locations: North America:+

Source: http://www.elit.ee/docs/horner/manuals/MAN0544-03.pdf

Untitled

INSTRUCTIONS • Each output has a built-in 3 hour safety timer INTRODUCTION • Tri-color LED and audible indicators for each outputindicates charge status, as well as for improper inputThank you for purchasing the PolyCharge4 lithium-polymervoltage, output reverse polarity, open-circuit, and morecharger! Capable of charging 4 separate lithium-polymer packs• Built-in fan keeps

Microsoft word - document

Malaria is a serious disease caused by one of five species of Plasmodium (a parasite). It is a medical emergency, treatable, and largely preventable. P falciparum - one of the two most common types of malaria, primarily found in Africa. It can cause severe disease and can be rapidly fatal. P vivax - the other most common type of malaria. It can stay in the body for years and cause relapses

Copyright © 2014 Articles Finder